Imagem |
Nº de peças |
Fabricante |
Descrição |
pacote |
Estoque |
Quantidade |
Connector Type | Current - IEC | Voltage - IEC | Current - UL | Voltage - UL | Filter Type | Fuse | Number of Positions | Mounting Type | Termination | Switch Features | Features | Fuse Holder, Drawer | Panel Cutout Dimensions | Panel Thickness | Material Flammability Rating | Ingress Protection | Approvals |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schurter Inc. |
IP67 IEC 60320 C14 INLET, QC, 4.
|
pacote: - |
Estoque5.742 |
|
Receptacle, Male Blades | 10A | 250VAC | 15A | 250VAC | Unfiltered - Commercial | No | 3 | Panel Mount, Bulkhead | Quick Connect - 0.189" (4.8mm) | - | Gasket | - | - | 0.236" (6.00mm) | UL94 V-0 | IP69K - Dust Tight, Water Resistant, Waterproof | cURus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque3.240 |
|
Receptacle, Male Blades - Module | 10A | 250VAC | 10A | 125VAC | Filtered (EMI, RFI) - Commercial, Medical | Yes | 3 | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | - | - | Fuse Holder | Rectangular - 32.00mm x 29.00mm | 0.031" ~ 0.118" (0.79mm ~ 3.00mm) | UL94 V-0 | IP40 | cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque7.038 |
|
Receptacle, Male Blades - Module | 8A | 250VAC | 8A | 125VAC | Filtered (EMI, RFI) - Commercial, Medical | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | - | Fuse Holder | Rectangular - 32.00mm x 29.00mm | - | UL94 V-0 | IP40 | cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque7.434 |
|
Receptacle, Male Blades - Module | 1A | 250VAC | 1A | 125VAC | Filtered (EMI, RFI) - Commercial, Medical | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | - | Fuse Holder | Rectangular - 32.00mm x 29.00mm | - | UL94 V-0 | IP40 | cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque6.840 |
|
Receptacle, Male Blades - Module | 6A | 250VAC | 6A | 125VAC | Filtered (EMI, RFI) - Commercial, Medical | Yes | 3 | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | - | - | Fuse Holder | Rectangular - 32.00mm x 29.00mm | 0.031" ~ 0.118" (0.79mm ~ 3.00mm) | UL94 V-0 | IP40 | cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque8.658 |
|
Receptacle, Male Blades - Module | 10A | 250VAC | 10A | 125VAC | Filtered (EMI, RFI) - Commercial, Medical | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | - | Fuse Holder | Rectangular - 32.00mm x 29.00mm | - | UL94 V-0 | IP40 | cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque3.690 |
|
Receptacle, Male Blades - Module | 2A | 250VAC | 2A | 125VAC | Filtered (EMI, RFI) - Commercial, Medical | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | - | Fuse Holder | Rectangular - 32.00mm x 29.00mm | - | UL94 V-0 | IP40 | cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque5.418 |
|
Receptacle, Male Blades - Module | 2A | 250VAC | 2A | 125VAC | Filtered (EMI, RFI) - Commercial, Medical | Yes | 3 | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | - | - | Fuse Holder | Rectangular - 32.00mm x 29.00mm | 0.031" ~ 0.118" (0.79mm ~ 3.00mm) | UL94 V-0 | IP40 | cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque2.232 |
|
Receptacle, Male Blades - Module | 4A | 250VAC | 4A | 125VAC | Filtered (EMI, RFI) - Commercial, Medical | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | - | Fuse Holder | Rectangular - 32.00mm x 29.00mm | - | UL94 V-0 | IP40 | cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque4.554 |
|
Receptacle, Male Blades - Module | 6A | 250VAC | 6A | 125VAC | Filtered (EMI, RFI) - Commercial, Medical | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | - | Fuse Holder | Rectangular - 32.00mm x 29.00mm | - | UL94 V-0 | IP40 | cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque7.812 |
|
Receptacle, Male Blades - Module | 4A | 250VAC | 4A | 125VAC | Filtered (EMI, RFI) - Commercial, Medical | Yes | 3 | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | - | - | Fuse Holder | Rectangular - 32.00mm x 29.00mm | 0.031" ~ 0.118" (0.79mm ~ 3.00mm) | UL94 V-0 | IP40 | cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque2.448 |
|
Receptacle, Male Blades - Module | 1A | 250VAC | 1A | 125VAC | Filtered (EMI, RFI) - Commercial, Medical | Yes | 3 | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | - | - | Fuse Holder | Rectangular - 32.00mm x 29.00mm | 0.031" ~ 0.118" (0.79mm ~ 3.00mm) | UL94 V-0 | IP40 | cULus, ENEC |
||
Schurter Inc. |
PWR ENT RCPT IEC320-C14 PANEL QC
|
pacote: - |
Estoque4.752 |
|
Receptacle, Male Blades | 8A | 250VAC | 8A | 125VAC | Filtered (EMI, RFI) - Commercial | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | Shielded | Fuse Holder | Rectangular - 36.00mm x 33.50mm | - | UL94 V-0 | IP65 - Dust Tight, Water Resistant | cULus, ENEC |
||
Schurter Inc. |
PWR ENT RCPT IEC320-C14 PANEL QC
|
pacote: - |
Estoque8.766 |
|
Receptacle, Male Blades | 8A | 250VAC | 8A | 125VAC | Filtered (EMI, RFI) - Commercial | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | Shielded | Fuse Holder | Rectangular - 36.00mm x 32.20mm | - | UL94 V-0 | IP65 - Dust Tight, Water Resistant | cULus, ENEC |
||
Schurter Inc. |
PWR ENT RCPT IEC320-C14 PANEL QC
|
pacote: - |
Estoque4.536 |
|
Receptacle, Male Blades | 6A | 250VAC | 6A | 125VAC | Filtered (EMI, RFI) - Commercial | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | Shielded | Fuse Holder | Rectangular - 36.00mm x 33.50mm | - | UL94 V-0 | IP65 - Dust Tight, Water Resistant | cULus, ENEC |
||
Schurter Inc. |
PWR ENT RCPT IEC320-C14 PANEL QC
|
pacote: - |
Estoque7.776 |
|
Receptacle, Male Blades | 6A | 250VAC | 6A | 125VAC | Filtered (EMI, RFI) - Commercial | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | Shielded | Fuse Holder | Rectangular - 36.00mm x 32.20mm | - | UL94 V-0 | IP65 - Dust Tight, Water Resistant | cULus, ENEC |
||
Schurter Inc. |
PWR ENT RCPT IEC320-C14 PANEL QC
|
pacote: - |
Estoque3.636 |
|
Receptacle, Male Blades | 2A | 250VAC | 2A | 125VAC | Filtered (EMI, RFI) - Commercial | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | Shielded | Fuse Holder | Rectangular - 36.00mm x 33.50mm | - | UL94 V-0 | IP65 - Dust Tight, Water Resistant | cULus, ENEC |
||
Schurter Inc. |
PWR ENT RCPT IEC320-C14 PANEL QC
|
pacote: - |
Estoque7.794 |
|
Receptacle, Male Blades | 2A | 250VAC | 2A | 125VAC | Filtered (EMI, RFI) - Commercial | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | Shielded | Fuse Holder | Rectangular - 36.00mm x 32.20mm | - | UL94 V-0 | IP65 - Dust Tight, Water Resistant | cULus, ENEC |
||
Schurter Inc. |
PWR ENT RCPT IEC320-C14 PANEL QC
|
pacote: - |
Estoque5.634 |
|
Receptacle, Male Blades | 1A | 250VAC | 1A | 125VAC | Filtered (EMI, RFI) - Commercial | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | Shielded | Fuse Holder | Rectangular - 36.00mm x 33.50mm | - | UL94 V-0 | IP65 - Dust Tight, Water Resistant | cULus, ENEC |
||
Schurter Inc. |
PWR ENT RCPT IEC320-C14 PANEL QC
|
pacote: - |
Estoque6.894 |
|
Receptacle, Male Blades | 1A | 250VAC | 1A | 125VAC | Filtered (EMI, RFI) - Commercial | Yes | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | Shielded | Fuse Holder | Rectangular - 36.00mm x 32.20mm | - | UL94 V-0 | IP65 - Dust Tight, Water Resistant | cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque3.474 |
|
Receptacle, Male Blades - Module | 6A | 250VAC | 6A | 125VAC | Filtered (EMI, RFI) - Commercial | No | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | Switch On-Off | Shielded, V-Lock Notch | - | Rectangular - 30.40mm x 34.40mm | - | UL94 V-0 | IP40 | CQC, cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque4.680 |
|
Receptacle, Male Blades - Module | 2A | 250VAC | 2A | 125VAC | Filtered (EMI, RFI) - Commercial | No | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | Switch On-Off | Shielded, V-Lock Notch | - | Rectangular - 30.40mm x 34.40mm | - | UL94 V-0 | IP40 | CQC, cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque8.334 |
|
Receptacle, Male Blades - Module | 2A | 250VAC | 2A | 125VAC | Filtered (EMI, RFI) - Commercial | No | 3 | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | Switch On-Off | Shielded, V-Lock Notch | - | Rectangular - 29.40mm x 33.10mm | 0.039" ~ 0.118" (1.00mm ~ 3.00mm) | UL94 V-0 | IP40 | CQC, cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque7.344 |
|
Receptacle, Male Blades - Module | 1A | 250VAC | 1A | 125VAC | Filtered (EMI, RFI) - Commercial | No | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | Switch On-Off | Shielded, V-Lock Notch | - | Rectangular - 30.40mm x 34.40mm | - | UL94 V-0 | IP40 | CQC, cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque6.516 |
|
Receptacle, Male Blades - Module | 1A | 250VAC | 1A | 125VAC | Filtered (EMI, RFI) - Commercial | No | 3 | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | Switch On-Off | Shielded, V-Lock Notch | - | Rectangular - 29.40mm x 33.10mm | 0.039" ~ 0.118" (1.00mm ~ 3.00mm) | UL94 V-0 | IP40 | CQC, cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque2.934 |
|
Receptacle, Male Blades - Module | 6A | 250VAC | 6A | 125VAC | Filtered (EMI, RFI) - Commercial | No | 3 | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | Switch On-Off | Shielded, V-Lock Notch | - | Rectangular - 29.40mm x 33.10mm | 0.039" ~ 0.118" (1.00mm ~ 3.00mm) | UL94 V-0 | IP40 | CQC, cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque4.968 |
|
Receptacle, Male Blades - Module | 4A | 250VAC | 4A | 125VAC | Filtered (EMI, RFI) - Commercial | No | 3 | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | Switch On-Off | Shielded, V-Lock Notch | - | Rectangular - 30.40mm x 34.40mm | - | UL94 V-0 | IP40 | CQC, cULus, ENEC |
||
Schurter Inc. |
PWR ENT MOD RCPT IEC320-C14 PNL
|
pacote: - |
Estoque7.632 |
|
Receptacle, Male Blades - Module | 4A | 250VAC | 4A | 125VAC | Filtered (EMI, RFI) - Commercial | No | 3 | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | Switch On-Off | Shielded, V-Lock Notch | - | Rectangular - 29.40mm x 33.10mm | 0.039" ~ 0.118" (1.00mm ~ 3.00mm) | UL94 V-0 | IP40 | CQC, cULus, ENEC |