Imagem |
Nº de peças |
Fabricante |
Descrição |
pacote |
Estoque |
Quantidade |
Impulse Discharge Current (8/20µs) | Tolerance | Number of Poles | Fail Short | Mounting Type | Package / Case |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Bourns Inc. |
GDT 90V 20% 5KA T/H FAIL SHORT
|
pacote: Axial Cylinder, 3 Lead (Radial Bend) |
Estoque7.920 |
|
5000A (5kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
||
Bourns Inc. |
GDT 200V 20% 5KA T/H FAIL SHORT
|
pacote: Axial Cylinder, 3 Lead (Radial Bend) |
Estoque2.556 |
|
5000A (5kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
||
Bourns Inc. |
GDT 145V 20% 5KA T/H FAIL SHORT
|
pacote: Axial Cylinder, 3 Lead (Radial Bend) |
Estoque3.384 |
|
5000A (5kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
||
Bourns Inc. |
GDT 470V 20% 5KA T/H FAIL SHORT
|
pacote: Axial Cylinder, 3 Lead (Radial Bend) |
Estoque5.256 |
|
5000A (5kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
||
Bourns Inc. |
GDT 420V 20% 5KA T/H FAIL SHORT
|
pacote: Axial Cylinder, 3 Lead (Radial Bend) |
Estoque5.220 |
|
5000A (5kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
||
Bourns Inc. |
GDT 250V 20% 5KA T/H FAIL SHORT
|
pacote: Axial Cylinder, 3 Lead (Radial Bend) |
Estoque6.120 |
|
5000A (5kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
||
Bourns Inc. |
GDT 230V 20% 5KA T/H FAIL SHORT
|
pacote: Axial Cylinder, 3 Lead (Radial Bend) |
Estoque3.204 |
|
5000A (5kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
||
Bourns Inc. |
GDT 200V 20% 5KA T/H FAIL SHORT
|
pacote: Axial Cylinder, 3 Lead (Radial Bend) |
Estoque2.034 |
|
5000A (5kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
||
Bourns Inc. |
GDT 600V 20% 5KA T/H FAIL SHORT
|
pacote: Axial Cylinder, 3 Lead (Radial Bend) |
Estoque5.814 |
|
5000A (5kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
||
Bourns Inc. |
GAS DISCHARGE TUBE
|
pacote: 2-SMD Cylinder Square End |
Estoque6.228 |
|
20000A (20kA) | ±20% | 1 | No | Surface Mount | 2-SMD Cylinder Square End |
||
Bourns Inc. |
GAS DISCHARGE TUBE
|
pacote: 2-SMD Cylinder Square End |
Estoque3.618 |
|
20000A (20kA) | ±20% | 1 | No | Surface Mount | 2-SMD Cylinder Square End |
||
Bourns Inc. |
GDT 420V 20% 20KA
|
pacote: Cylinder No Lead, 3 Terminal |
Estoque8.712 |
|
20000A (20kA) | ±20% | 3 | No | User Defined | Cylinder No Lead, 3 Terminal |
||
Bourns Inc. |
GDT 250V 20% 20KA
|
pacote: Cylinder No Lead, 3 Terminal |
Estoque2.034 |
|
20000A (20kA) | ±20% | 3 | No | User Defined | Cylinder No Lead, 3 Terminal |
||
Bourns Inc. |
GDT 350V 30% 10KA THROUGH HOLE
|
pacote: Axial Cylinder |
Estoque7.686 |
|
10000A (10kA) | ±30% | 2 | No | Through Hole | Axial Cylinder |
||
Bourns Inc. |
GDT 420V 20% 5KA SURFACE MOUNT
|
pacote: 3-SMD Cylinder Square End |
Estoque5.940 |
|
5000A (5kA) | ±20% | 3 | No | Surface Mount | 3-SMD Cylinder Square End |
||
Bourns Inc. |
GDT 350V 20% 5KA SURFACE MOUNT
|
pacote: 3-SMD Cylinder Square End |
Estoque2.862 |
|
5000A (5kA) | ±20% | 3 | No | Surface Mount | 3-SMD Cylinder Square End |
||
Bourns Inc. |
GDT 300V 20% 5KA SURFACE MOUNT
|
pacote: 3-SMD Cylinder Square End |
Estoque4.338 |
|
5000A (5kA) | ±20% | 3 | No | Surface Mount | 3-SMD Cylinder Square End |
||
Bourns Inc. |
GAS DISCHARGE TUBE
|
pacote: 2-SMD Cylinder Square End |
Estoque2.052 |
|
20000A (20kA) | ±20% | 1 | No | Surface Mount | 2-SMD Cylinder Square End |
||
Bourns Inc. |
GAS DISCHARGE TUBE
|
pacote: 2-SMD Cylinder Square End |
Estoque7.902 |
|
20000A (20kA) | ±20% | 1 | No | Surface Mount | 2-SMD Cylinder Square End |
||
Bourns Inc. |
GAS DISCHARGE TUBE
|
pacote: 2-SMD Cylinder Square End |
Estoque3.150 |
|
20000A (20kA) | ±20% | 1 | No | Surface Mount | 2-SMD Cylinder Square End |
||
Bourns Inc. |
GAS DISCHARGE TUBE
|
pacote: 2-SMD Cylinder Square End |
Estoque3.078 |
|
20000A (20kA) | ±20% | 1 | No | Surface Mount | 2-SMD Cylinder Square End |
||
Bourns Inc. |
GAS DISCHARGE TUBE
|
pacote: 2-SMD Cylinder Square End |
Estoque7.776 |
|
20000A (20kA) | ±20% | 1 | No | Surface Mount | 2-SMD Cylinder Square End |
||
Bourns Inc. |
GDT 500V 10KA 2 POLE
|
pacote: Disc 8.00mm Tabbed SMD |
Estoque3.852 |
|
10000A (10kA) | ±20% | 2 | No | Surface Mount Vertical | Disc 8.00mm Tabbed SMD |
||
Bourns Inc. |
GDT 6000V 20% 5KA THROUGH HOLE
|
pacote: Axial Cylinder |
Estoque3.060 |
|
5000A (5kA) | ±20% | 2 | No | Through Hole | Axial Cylinder |
||
Bourns Inc. |
GDT 5000V 20% 5KA THROUGH HOLE
|
pacote: Axial Cylinder |
Estoque7.344 |
|
5000A (5kA) | ±20% | 2 | No | Through Hole | Axial Cylinder |
||
Bourns Inc. |
GDT 420V 15% 10KA THROUGH HOLE
|
pacote: Axial Cylinder |
Estoque3.348 |
|
10000A (10kA) | ±15% | 2 | No | Through Hole | Axial Cylinder |
||
Bourns Inc. |
GDT 350V 15% 10KA THROUGH HOLE
|
pacote: Axial Cylinder |
Estoque2.754 |
|
10000A (10kA) | ±15% | 2 | No | Through Hole | Axial Cylinder |
||
Bourns Inc. |
GDT 230V 15% 10KA THROUGH HOLE
|
pacote: Axial Cylinder |
Estoque8.316 |
|
10000A (10kA) | ±15% | 2 | No | Through Hole | Axial Cylinder |